RealTime-Glo™ MT Cell Viability Assay
The RealTime-Glo™ MT Cell Viability Assay is a non-lytic assay that monitors cell viability continually in the same sample well up to 72 hours. Light production is proportional to the number of live cells in culture, with the reducing potential of viable cells measured via a NanoLuc® Luciferase reaction.
Bio-Science Kft. is the official Hungarian distributor of Promega. We provide quotes, technical advice and service in Hungary - request a quote.
Monitor Cell Viability in Real Time
- Save time, cell culture and reagent costs
- Rapidly detect changes in cell viability
With the RealTime-Glo™ MT Cell Viability Assay, you can monitor cell viability continually in the same sample well up to 72 hours to obtain more information about the mode of action of a treatment with regard to time and dose dependence. The assay reagent can be added to cells during plating, during treatment or at the end of treatment. No cell washing, media removal or further additions are required.
The nonlytic nature and rapid response of the assay make it possible to monitor cell viability over time in the same well, enabling easy multiplexing with other cell-based assays or downstream applications. The assay measures the reducing potential of viable cells and is ATP-independent, providing an orthogonal method for viability or cytotoxicity determination.
Assay Principle
In the RealTime Glo™ MT Cell Viability Assay, a non-lytic NanoLuc® Luciferase reaction occurs in the culture medium. NanoLuc® Luciferase and MT Cell Viability Substrate are added to cell culture media. The MT Cell Viability Substrate then diffuses into cells where it is reduced to form a NanoLuc® Substrate, which exits the cell and is used rapidly by NanoLuc® Luciferase in the media. Only metabolically active cells can reduce the substrate, and light production is proportional to the number of live cells in culture. Dead cells cannot reduce the substrate.
Rapidly Detect Changes in Cell Viability
The RealTime-Glo™ MT Cell Viability Assay generates a luminescent signal that is dependent upon continuous reduction of the MT cell viability substrate by viable cells and rapid turnover by NanoLuc® Luciferase. Conventional assays based on reducing potential (alamarBlue, MTT) are accumulation-based and do not allow real-time detection of cell death in the same well.
Five hundred A549 cells were plated in medium containing the RealTime-Glo™ MT Reagents in 384-well plates and various concentrations of bortezomib. The luminescence signal was determined from each well every hour for 72 hours in a Tecan M200 plate reader with gas control module (37°C/5% CO2). Data from specific time points plotted to calculate EC50 at these time points.
Flexible Assay Setup
Perform real-time cell viability monitoring or endpoint detection. You decide how to set up your assay. Add the RealTime-Glo™ Reagent to cells at any time point when cell viability readings are desired. The assay is compatible with high-throughput screening in 96-, 384- and 1536-well plates.
Multiplex with Other Assays for More Information Per Sample
The nonlytic, live-cell RealTime-Glo™ Assay is compatible with downstream applications and allows multiplexing with other assays, conserving precious samples and providing more informative data per sample.
Source: Promega product page (updated 2026-10-31).
| Parameter | Value |
|---|---|
| Catalog Number G9711 (100 reactions): NanoLuc® Enzyme, 1,000X (Part # E499A) | 1 × 10μl |
| Catalog Number G9711 (100 reactions): MT Cell Viability Substrate, 1,000X (Part # G971A) | 1 × 10μl |
| Catalog Number G9712 (10 × 100 reactions): NanoLuc® Enzyme, 1,000X (Part # E499A) | 10 × 10μl |
| Catalog Number G9712 (10 × 100 reactions): MT Cell Viability Substrate, 1,000X (Part # G971A) | 10 × 10μl |
| Catalog Number G9713 (1,000 reactions): NanoLuc® Enzyme, 1,000X (Part # E499B) | 1 × 100μl |
| Catalog Number G9713 (1,000 reactions): MT Cell Viability Substrate, 1,000X (Part # G971B) | 1 × 100μl |